.. _digital_io: Digital Out =========== The out console command is used to control the value of the Digital Output Channel. The command takes DIO Channel as argument. Out Command ----------- The ``out`` command used to set the value of the Digital Output Channel. - **out** - outputs console - all - print all outputs - set - set output value (param: [0|1]) - get - get output value (param: ) Below is the example usage: .. code-block:: bash out get 0 0 : eval_DO_1 -> 0 ok 669810: RefApp: CONSOLE: INFO: Received console command "out get 0" 669812: RefApp: CONSOLE: INFO: Console command succeeded .. code-block:: bash out set 0 1 0 : eval_DO_1 -> ok ok 763772: RefApp: CONSOLE: INFO: Received console command "out set 0 1" 763776: RefApp: CONSOLE: INFO: Console command succeeded Digital In ========== The ``in`` console command is used to read the value of the Digital input Channel. The command takes DIO Channel as argument. In Command ---------- - **in** - inputs console - all - print all inputs, verbose output - get - get input value (param: ) - allx - all inputs Below is the example usage: .. code-block:: bash in get 0 dInput 0 -> 0 ok 302319: RefApp: CONSOLE: INFO: Received console command "in get 0" 302321: RefApp: CONSOLE: INFO: Console command succeeded Next: :ref:`adc_console`