Digital Out
The out console command is used to control the value of the Digital Output Channel. The command takes DIO Channel as argument.
Out Command
The out
command used to set the value of the Digital Output Channel.
- out - outputs console
all - print all outputs
set - set output value (param: <output-id> [0|1])
get - get output value (param: <output-id>)
Below is the example usage:
out get 0
0 : eval_DO_1 -> 0
ok
669810: RefApp: CONSOLE: INFO: Received console command "out get 0"
669812: RefApp: CONSOLE: INFO: Console command succeeded
out set 0 1
0 : eval_DO_1 -> ok
ok
763772: RefApp: CONSOLE: INFO: Received console command "out set 0 1"
763776: RefApp: CONSOLE: INFO: Console command succeeded
Digital In
The in
console command is used to read the value of the Digital input Channel.
The command takes DIO Channel as argument.
In Command
- in - inputs console
all - print all inputs, verbose output
get - get input value (param: <input-id>)
allx - all inputs
Below is the example usage:
in get 0
dInput 0 -> 0
ok
302319: RefApp: CONSOLE: INFO: Received console command "in get 0"
302321: RefApp: CONSOLE: INFO: Console command succeeded
Next: ADC Console